Sign In | Join Free | My spintoband.com
China Zhuhai SNOVA Technology (HongKong) Co., Ltd logo
Zhuhai SNOVA Technology (HongKong) Co., Ltd
Zhuhai SNOVA Technology (HongKong) Co., Ltd NO MOQ! SAMPLE ARE AVAILABLE!
Active Member

3 Years

Home > Overhead Line Fault Indicator >

Overhead Short Circuit and Grounding Fault Indicator Installation tool

Zhuhai SNOVA Technology (HongKong) Co., Ltd

Overhead Short Circuit and Grounding Fault Indicator Installation tool

Brand Name : SNOVA

Model Number : SNV307

Certification : ISO

Place of Origin : CHINA

MOQ : 5sets

Payment Terms : L/C, D/A, D/P, Western Union

Supply Ability : 5000 piece each month

Delivery Time : 5working days

Packaging Details : with carton

Contact Now

Overhead Short Circuit and Grounding Fault Indicator Installation tool

SUMMARY

SNV308.1 series overhead type Fault Indicator system is based on the Sensor that through CT get the (6KV-50KV) line’s current signal, through smart computer chip(IC) by program calculating, Analysis ,judge the short circuit or ground fault. When Sensor detect the fault happen, then the Fault indicator warn the manager through turn red flag, and shine 3 color ultra-led. It is good for power managing user to find the fault happen reason and place, then fast solve the problem and make the power restore.

*SNV308.1 Fault Indicator with the aid of the remote control PDA(SNV306.1), User can read, reset the indicator’s setting parameter, and can read the online real time current etc

*SNV308.1 Fault Indicator with the aid of the professional control terminal equipment(SNV309.1) and Web server, it can achieve to remote read and manage the Fault indicator state on times.

There are two channels for reading and managing the remote fault indicators. One is through GSM mobile phone SMS command control. Second is user computer software control. Power managing user, can get the fault indicator information on times


The signals description of indicator
The fault indicator type Flag SNV308.1 has six ultra-bright, 360°3colors LED pointing to the around for
fault indication. Additionally it ha a yellow LED pointing to the bottom to signal its operational status.
1) short circuit permanent fault indicating: Six 3-color led will shine red color, and four times, every 2
second,And turn to red flag at same time.
2) short circuit temporary fault indicating: Six 3-color led will shine green color, and four times, every 2
second,And turn to red flag at same time.
3) Earth Fault indicating:Six 3-color led will shine Blue color, and four times, every 2 second. And turn to
red flag at same time.
yellow state Led light:
Battery voltage too low:Shine 1 time, every2second
Battery voltage low: shine 2 time, evey2second
Wireless setting state: shine 4 times, every 2 second
Operational settings and functions of the SNV308.1
The operational settings of the fault indicator can be adjusted and read out with the remote control , Flag type
SNV306.1. Detailed information about all functions of the indicator basic settings like trip current and advanced
settings like the auto re closer settings can be found in the instruction manual for the remote control, Flag type
SNV306.1. Information how to change or read out the settings can be also found there.


Please note: The online current can be read out with the remote control, Flag type
SNV306.1

Careful handling
When moving the adapter down to the ground, please move it downwards vertically. When placing it
onto the ground horizontally the connection to the hot stick might break.




Wholesale Overhead Short Circuit and Grounding Fault Indicator Installation tool from china suppliers

Overhead Short Circuit and Grounding Fault Indicator Installation tool Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhuhai SNOVA Technology (HongKong) Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0